1,374 research outputs found

    genetic optimization for economic feasibility of refurbishment in buildings

    Get PDF
    Abstract This paper investigates the possibility to enhance the thermal characteristics of a building fabric taking into account the economic feasibility in order to avoid useless expensive interventions. The problem consists in realizing an internal insulation system for a single apartment located in Trieste. A genetic optimization has been implemented in order to search a large number of solutions with multiple objects and constraints. EnergyPlus has been used for dynamic building and plant simulation and modeFRONTIER for optimization loop setup. The objectives are the used heating energy consumption and the life cycle refurbishment cost, using a net present value approach. An additional objective has been added in order to guarantee the maximization of the interior useful floor area, which is directly influenced by the internal insulation thickness. Different approaches have been compared, considering actions dealing with opaque surfaces only or considering the replacement of existing windows. The paper demonstrates that an automatic optimization approach can help designers to identify the best suited intervention for building refurbishment

    The Low Energy Tagger for the KLOE-2 experiment

    Full text link
    The KLOE experiment at the upgraded DAFNE e+e- collider in Frascati (KLOE-2) is going to start a new data taking at the beginning of 2010 with its detector upgraded with a tagging system for the identification of gamma-gamma interactions. The tagging stations for low-energy e+e- will consist in two calorimeters The calorimeter used to detect low-energy e+e- will be placed between the beam-pipe outer support structure and the inner wall of the KLOE drift chamber. This calorimeter will be made of LYSO crystals readout by Silicon Photomultipliers, to achieve an energy resolution better than 8% at 200 MeV.Comment: 4 pages, 5 figures, in the proceedings of "Frontier detectors for frontier physics", isola d'Elba, Italy, May 200

    Functional Brain Connectivity Patterns Associated with Visual Hallucinations in Dementia with Lewy Bodies

    Get PDF
    The supplementary material is available in the electronic version of this article: https://doi.org/ 10.3233/ADR-200288.Copyright © 2021 – The authors. Background: The presence of recurrent, complex visual hallucinations (VH) is among the core clinical features of dementia with Lewy bodies (DLB). It has been proposed that VH arise from a disrupted organization of functional brain networks. However, studies are still limited, especially investigating the resting-state functional brain features underpinning VH in patients with dementia. Objective: The aim of the present pilot study was to investigate whether there were any alterations in functional connectivity associated with VH in DLB. Methods: Seed-based analyses and independent component analysis (ICA) of resting-state fMRI scans were carried out to explore differences in functional connectivity between DLB patients with and without VH. Results: Seed-based analyses reported decreased connectivity of the lateral geniculate nucleus, the superior parietal lobule and the putamen with the medial frontal gyrus in DLB patients with VH. Visual areas showed a pattern of both decreased and increased functional connectivity. ICA revealed between-group differences in the default mode network (DMN). Conclusion: Functional connectivity analyses suggest dysfunctional top-down and bottom-up processes and DMN-related alterations in DLB patients with VH. This impairment might foster the generation of false visual images that are misinterpreted, ultimately resulting in VH.Faculty of Medicine, Dentistry and Health, University of Sheffield, UK matched funding studentship

    Measurement of neutron detection efficiency between 22 and 174 MeV using two different kinds of Pb-scintillating fiber sampling calorimeters

    Full text link
    We exposed a prototype of the lead-scintillating fiber KLOE calorimeter to neutron beam of 21, 46 and 174 MeV at The Svedberg Laboratory, Uppsala, to study its neutron detection efficiency. This has been found larger than what expected considering the scintillator thickness of the prototype. %To check our method, we measured also the neutron %detection efficiency of a 5 cm thick NE110 scintillator. We show preliminary measurement carried out with a different prototype with a larger lead/fiber ratio, which proves the relevance of passive material to neutron detection efficiency in this kind of calorimeters

    Higher ventricular-arterial coupling derived from three-dimensional echocardiography is associated with a worse clinical outcome in systemic sclerosis

    Get PDF
    Primary myocardial involvement is common in systemic sclerosis (SSc). Ventricular-arterial coupling (VAC) reflecting the interplay between ventricular performance and arterial load, is a key determinant of cardiovascular (CV) performance. We aimed to investigate VAC, VAC-derived indices, and the potential association between altered VAC and survival free from death/hospitalization for major adverse CV events (MACE) in scleroderma. Only SSc patients without any anamnes-tic and echocardiographic evidence of primary myocardial involvement who underwent three-dimensional echocardiography (3DE) were included in this cross-sectional study and compared with healthy matched controls. 3DE was used for noninvasive measurements of end-systolic elastance (Ees), arterial elastance (Ea), VAC (Ea/Ees) and end-diastolic elastance (Eed); the occurrence of death/hospitalization for MACE was recorded during follow-up. Sixty-five SSc patients (54 female; aged 56 ± 14 years) were included. Ees (p = 0.04), Ea (p = 0.04) and Eed (p = 0.01) were higher in patients vs. controls. Thus, VAC was similar in both groups. Ees was lower and VAC was higher in patients with diffuse cutaneous form (dcSSc) vs. patients with limited form (lcSSc) (p = 0.001 and p = 0.02, respectively). Over a median follow-up of 4 years, four patients died for heart failure and 34 were hospitalized for CV events. In patients with VAC >0.63 the risk of MACE was higher (HR 2.5; 95% CI 1.13–5.7; p = 0.01) and survival free from death/hospitalization was lower (p = 0.005) than in those with VAC < 0.63. Our study suggests that VAC may be impaired in SSc patients without signs and symptoms of primary myocardial involvement. Moreover, VAC appears to have a prognostic role in SSc

    Níveis de metano e perdas energéticas em bovinos de corte, suplementados ou não, em pastagem de capim mombaça (Panicum maximum cv. Mombaça).

    Get PDF
    Objetivou-se avaliar o impacto da suplementação protéico-energética na emissão de metano (CH4) de novilhos, durante a recria, em pastagem de capim-mombaça. Os tratamentos avaliados foram: T0 ? Apenas suplementação mineral; T1 ? Suplementação protéico-energética. Utilizou-se a técnica do gás traçador interno hexafluoreto de enxofre (SF6) para estimar a emissão diária de CH4. Foram utilizados 20 animais, sendo dez de cada tratamento, em dois ensaios, com medição de CH4 em cinco dias consecutivos. Na análise estatística dos dados de emissão de CH4 , utilizou-se a metodologia de modelos mistos para medidas repetidas do SAS. Os animais foram também avaliados quanto à eficiência de utilização do alimento, utilizando-se como critério o consumo alimentar residual (CAR). Animais suplementados e não suplementados não diferiram (P>0,05) quanto à produção diária de metano e quanto à perda total diária de energia na forma de CH4. Entretanto, quando a perda de energia foi expressa em g/kg de matéria seca consumida (21,51 vs. 29,76 g/kg) e como porcentagem da energia bruta (EB) ingerida (6,36 versus 8,59 %), os animais suplementados tiveram menores perdas (P0,05) quanto aos níveis de emissão de metano (total ou por kg de matéria seca ? MS ingerida). Assim, conclui-se que: a suplementação com concentrado age de forma efetiva na mitigação da emissão de metano; diferenças no CAR não podem ser atribuídas a diferenças nos níveis de emissão de metano

    Study of the a_0(980) meson via the radiative decay phi->eta pi^0 gamma with the KLOE detector

    Full text link
    We have studied the phi->a_0(980) gamma process with the KLOE detector at the Frascati phi-factory DAPhNE by detecting the phi->eta pi^0 gamma decays in the final states with eta->gamma gamma and eta->pi^+ pi^- pi^0. We have measured the branching ratios for both final states: Br(phi->eta pi^0 gamma)=(7.01 +/- 0.10 +/- 0.20)x10^-5 and (7.12 +/- 0.13 +/- 0.22)x10^-5 respectively. We have also extracted the a_0(980) mass and its couplings to eta pi^0, K^+ K^-, and to the phi meson from the fit of the eta pi^0 invariant mass distributions using different phenomenological models.Comment: 17 pages, 6 figures, submitted to Physics Letters B. Corrected typos in eq.

    A global fit to determine the pseudoscalar mixing angle and the gluonium content of the eta' meson

    Full text link
    We update the values of the eta-eta' mixing angle and of the eta' gluonium content by fitting our measurement R_phi = BR(phi to eta' gamma)/ BR(phi to eta gamma) together with several vector meson radiative decays to pseudoscalars (V to P gamma), pseudoscalar mesons radiative decays to vectors (P to V gamma) and the eta' to gamma gamma, pi^0 to gamma gamma widths. From the fit we extract a gluonium fraction of Z^2_G = 0.12 +- 0.04, the pseudoscalar mixing angle psi_P = (40.4 +- 0.6) degree and the phi-omega mixing angle psi_V = (3.32 +- 0.09) degree. Z^2_G and psi_P are fairly consistent with those previously published. We also evaluate the impact on the eta' gluonium content determination of future experimental improvements of the eta' branching ratios and decay width.Comment: 13 pages, 7 figures to submit to JHE

    Measurement of the neutron detection efficiency of a 80% absorber - 20% scintillating fibers calorimeter

    Full text link
    The neutron detection efficiency of a sampling calorimeter made of 1 mm diameter scintillating fibers embedded in a lead/bismuth structure has been measured at the neutron beam of the The Svedberg Laboratory at Uppsala. A significant enhancement of the detection efficiency with respect to a bulk organic scintillator detector with the same thickness is observed.Comment: 10 pages, 7 figure

    Precision Measurement of KS Meson Lifetime with the KLOE detector

    Get PDF
    Using a large sample of pure, slow, short lived K0 mesons collected with KLOE detector at DaFne, we have measured the KS lifetime. From a fit to the proper time distribution we find tau = (89.562 +- 0.029_stat +- 0.043_syst) ps. This is the most precise measurement today in good agreement with the world average derived from previous measurements. We observe no dependence of the lifetime on the direction of the Ks.Comment: 5 pages, 7 figure
    corecore